Description
Hi,
When I use this run card with sherpa version 2.1.1
http://t3serv001.mit.edu/~anlevin/for_sherpa_ticket_15Dec2014/sherpa_run.dat
I see this output
http://t3serv001.mit.edu/~anlevin/for_sherpa_ticket_15Dec2014/sherpa_output_5.txt
There are two kinds of messages I am worried about:
1) ZAlign::ZAlign(): Q = 85.4593 vs. 12.2497, rel. diff. -nan
and
2)
Amplitude::GaugeTest(): Large deviation {
2.46869973838e-26
vs 2.46869973874e-26 => -1.48038581393e-10
}
I noticed that when I use Order_EW 4; Order_QCD 2; instead of Order_EW 6; Order_QCD 0; neither problem occurs.
Thanks.
Andrew
Attachments (0)
Change History (2)
comment:1 Changed 10 years ago by
comment:2 Changed 10 years ago by
Resolution: | → worksforme |
---|---|
Status: | new → closed |
Please reopen ticket if the problem persists.
Note: See
TracTickets for help on using
tickets.
Hi Andrew,
the gauge violations are very small and might well be just a numerical issue. The ZAlign warnings should disappear upon using EXCLUSIVE_CLUSTER_MODE=1 (on the command line or in the (run) section).