Modify ↓
#125 closed defect (fixed)
Flux missing when calculating decay widths
Reported by: | Frank Siegert | Owned by: | Frank Siegert |
---|---|---|---|
Priority: | major | Milestone: | |
Component: | Unknown | Version: | 1.2.3 |
Keywords: | Cc: |
Description
When decay widths are calculated in the processes section, e.g.
(processes){ Process : 23 -> 11 -11 End process }(processes)
then the final number doesn't include the flux factor 1/(2M) due to a recent change in the phase space handler.
Attachments (1)
Change History (3)
Changed 14 years ago by
Attachment: | decays-flux.patch added |
---|
comment:1 Changed 14 years ago by
Resolution: | → fixed |
---|---|
Status: | new → closed |
Note: See
TracTickets for help on using
tickets.
Fixed by the attached patch: